Mazda 3 manuals

Mazda 3 Service Manual: Electro Hydraulic Power Assist Steering (EHPAS) Control Module Inspection

Mazda 3 Service Manual / Steering / Linkage, Power / Electro Hydraulic Power Assist Steering (EHPAS) Control Module Inspection

Terminal Voltage Table (Reference)



Terminal

Signal name

Connected to

Measured item

Measured terminal (measured condition)

Standard

Inspection item(s)

1A

Ground

Ground point

Voltage

Under any condition

1 V or less

  • Wiring harness (1A—ground point)

1B

Battery power supply

Battery

Voltage

Under any condition

B+

  • Wiring harness (1B—battery)

  • Fuse (EHPAS 80A)

2A

2B

CAN_L

Inspect under DTC inspection.

2C

2D

CAN_H

Inspect under DTC inspection.

2E

2F

Ignition power supply

Ignition switch or IG1 relay

Voltage

Switch the ignition to ON

B+

  • Wiring harness (2F—ignition switch or IG1 relay—battery)

  • Fuse (ABS IG 7.5A)

Switch the ignition to off

1 V or less


Electro Hydraulic Power Assist Steering (EHPAS) Control Module Configuration
CAUTION: If the EHPAS CM configuration is not completed, the EHPAS will not operate properly. If the EHPAS CM is replaced, always carry out the EHPAS CM configuration so that the EHPAS o ...

Oil Control Valve (OCV) Inspection [Mzr 2.0, Mzr 2.5]
Coil Resistance Inspection 1. Remove the battery cover.. 2. Disconnect the negative battery cable.. 3. Remove the plug hole plate.. 4. Disconnect the OCV connector. 5. Measure the resistance ...

Other materials:

ABS HU/CM Inspection
1. Disconnect the ABS HU/CM connector.. 2. Connect the negative battery cable.. 3. Attach the tester lead to the ABS HU/CM wiring harness-side connector and inspect the voltage, continuity, or resistance according to the standard (reference value) in the table below. Standard (reference) ...

Active Command Modes Inspection [Blind Spot Monitoring (Bsm)]
1. Connect the M-MDS (IDS) to the DLC-2. 2. After the vehicle is identified, select the following items from the initialization screen of the IDS. a. Select “DataLogger”. b. Select “Modules”. c. Select “BSML” or “BSMR”. 3. Select the simulation items from the PID table. 4. Perform ...

Vanity Mirror Illumination Inspection
1. Disconnect the negative battery cable.. 2. Remove the sunvisor.. 3. Verify that the continuity between the vanity mirror illumination terminals is as indicated in the table. If not as indicated in the table, inspect the bulb. If there is no malfunction, replace the sunvisor. ...

© 2016-2024 Copyright www.mazda3tech.com