1. Remove the battery cover..
2. Disconnect the negative battery cable and wait 1 min or more
..
3. Disconnect the power seat switch connector.
4. Inspect for continuity between the power seat switch connector terminals using an ohmmeter.
If not as specified, replace the power seat switch.

Slide Motor Inspection
Wipers, WashersHazard Warning Flasher
The hazard warning lights should always
be used when you stop on or near a
roadway in an emergency.
The hazard warning lights warn other
drivers that your vehicle is a traffic hazard
and that they must take extreme caution
when near it.
Depress the hazard warning flasher and
all the tu ...
Air Bypass Valve Inspection [Mzr 2.3 Disi Turbo]
1. Remove the air bypass valve..
2. Connect the vacuum pump to the vacuum ports of the air bypass valve.
3. Verify that the airflow is as indicated in the table.
Vacuum
(kPa {mmHg, inHg})
Valve operation condition
Airflow between port A—B
...
Air Intake Actuator Inspection [Full Auto Air Conditioner]
1. Connect battery positive voltage to air intake actuator terminal B (or C),
connect terminal C (or B) to ground, and then verify that the air intake actuator
operates as shown in the table.
If the operation condition is not normal, replace the air intake actuator.
...