Mazda 3 manuals

Mazda 3 Service Manual: Slide Motor Inspection

Mazda 3 Service Manual / Body / Seats / Slide Motor Inspection

1. Remove the battery cover..

2. Disconnect the negative battery cable and wait 1 min or more

..

3. Disconnect the slide motor connector.

4. Apply battery positive voltage to the slide motor terminals and inspect the slide motor operation



Motor operation

Connection

B+

GND

Forward

D

B

Backward

B

D


Seat Weight Sensor Removal/Installation [Two Step Deployment Control System]
CAUTION: When the seat weight sensor is replaced with a new one, perform the seat weight sensor calibration using the M–MDS.. When replacing the seat weight sensor, replace it ...

Power Seat Switch Inspection
1. Remove the battery cover.. 2. Disconnect the negative battery cable and wait 1 min or more.. 3. Disconnect the power seat switch connector. 4. Inspect for continuity between the power seat sw ...

Other materials:

Electrical System
Electrical Parts Battery cable Before disconnecting connectors or removing electrical parts, disconnect the negative battery cable. Wiring Harness To remove the wiring harness from the clip in the engine room, pry up the hook of the clip using a flathead screwdriver. ...

Light Bulbs
WARNING Do not replace the xenon fusion bulbs yourself: Replacing the xenon fusion bulbs yourself is dangerous. Because the xenon fusion bulbs require high voltage, you could receive an electric shock if the bulbs are handled incorrectly. Consult an Authorized ...

Ignition Coil/Ion Sensor Removal/Installation [Skyactiv G 2.0]
1. Remove the battery cover.. 2. Disconnect the negative battery cable.. 3. Remove the plug hole plate.. 4. Remove the plug hole plate bracket.. 5. Remove in the order indicated in the table. 6. Install in the reverse order of removal. 1 Connector ...

� 2016-2026 Copyright www.mazda3tech.com