Voltage Inspection
NOTE:
The variable tumble shutter valve switch cannot be removed as a single unit. When replacing the variable tumble shutter valve switch, replace it together with the intake manifold as a single unit.
1. Connect the M-MDS to the DLC–2.

2. Switch the ignition to ON.
3. Verify that the variable tumble shutter valve switch output voltage (PID: IMRC_POS) is within the specification..
If not as specified, replace the intake manifold..
Throttle Position (TP) Sensor Inspection [Mzr 2.0, Mzr 2.5]
Variable Swirl Shutter Valve Switch Inspection [Mzr 2.3 Disi Turbo]Wheel Balance Adjustment
CAUTION:
Adjust the outer wheel balance first, then the inner wheel balance.
Be careful not to scratch the wheels.
Adhesive-type Balance Weight (Outer)
1. Remove the old balance weight from the wheel.
2. Remove the double-sided adhesive tape remaining on the wheel, then clea ...
Transaxle Oil Inspection [G35 M R]
1. Park the vehicle on level ground.
2. Remove the aerodynamic under cover No.2..
3. Remove the oil level plug and washer.
4. Verify that the oil is near the brim of the plug port.
If the oil level is lower than the low level, add the specified amount and
type of oil through the ...
Purge Solenoid Valve Inspection [Mzr 2.0, Mzr 2.5]
Airflow Inspection
1. Remove the battery cover..
2. Disconnect the negative battery cable..
3. Remove the purge solenoid valve..
4. Inspect airflow between the ports under the following conditions.
Measured condition
Continuity between A—B
...