1. Remove the rearview mirror..
2. Wind each end of a wire around a bar.

WARNING:
Using the piano wire with bare hands can cause injury. Always wear gloves when using the piano wire.
NOTE:
Use a long sawing action to spread the work over the whole length of the piano wire to prevent it from breaking.
3. Fix one end of the piano wire, and while pulling the other end, cut the sealant to remove the base.
Base Installation
Filament InspectionRear Wiper Motor Inspection
1. Disconnect the negative battery cable..
2. Remove the following parts:
a. Rear wiper arm and blade.
b. Liftgate upper trim.
c. Liftgate side trim.
d. Liftgate lower trim.
3. Disconnect the rear wiper motor connector.
4. Apply battery positive voltage to rear wiper motor connector te ...
Camshaft Position (CMP) Sensor Removal/Installation [Mzr 2.0, Mzr 2.5]
CAUTION:
When replacing the CMP sensor, make sure there is no foreign material on
it such as metal shavings. If it is installed with foreign material, the sensor
output signal will malfunction resulting from fluctuation in magnetic flux and
cause a deterioration in engine control.
...
Air Bleeding
CAUTION:
If the strainer is removed, impurities may penetrate the power steering system
and damage it. To prevent this, always bleed air with the strainer installed.
Do not maintain the steering wheel fully turned for 5 s or more. The oil
temperature could rise and damage ...