1. Remove the plug hole plate in the order indicated in the figure.
NOTE:
Lift off and remove the plug hole plate from the installation areas as shown in the figure.

2. Install the plug hole plate in the reverse order of removal.
Non Return Valve Inspection [Skyactiv G 2.0]
Variable Swirl Shutter Valve Actuator Inspection [Mzr 2.3 Disi Turbo]Rear Power Window Regulator Removal/Installation
1. Fully lower the rear door glass.
2. Disconnect the negative battery cable..
3. Remove the rear door trim..
4. Remove the service hole cover.
5. Remove the rear door speaker..
6. Remove the glass guide..
7. Remove the rear power window motor..
8. Remove the rear door glass..
9. ...
Power Window System Preliminary Inspection [Power Window System]
Manual Open/close Function Inspection
STEP
INSPECTION
ACTION
1
Switch the ignition to ON.
Operate the power window using the manual open/close function on
the power window main switch.
...
Instrument Cluster Configuration
1. Connect the M-MDS (IDS) to the DLC-2.
2. After the vehicle is identified, select the following items from the initialization
screen of the IDS.
Select the “Module Programming”.
3. Then, select items from the screen menu in the following order.
Select “Programmable Mo ...