Mazda 3 manuals

Mazda 3 Service Manual: Up Switch Inspection [Fw6 A EL]

Mazda 3 Service Manual / Drivetrain / Transmission/Transaxle / Automatic / Up Switch Inspection [Fw6 A EL]

Continuity Inspection

NOTE:

1. Remove the battery cover..

2. Disconnect the negative battery cable..

3. Remove the console..

4. Disconnect the selector lever component connector.


5. Verify that the continuity between selector lever component terminals B and H.


Up switch specification

Test condition

Continuity

Selector lever is in the M position (+) side position.

Continuity

Selector lever is not in the M position (+) side position.

No continuity


Up Switch Inspection [FS5 A EL]
1. Perform the following procedures. a. Remove the battery cover.. b. Disconnect the negative battery cable. c. Remove the console.. d. Disconnect the selector lever component connector. ...

Automatic Transmission Control
...

Other materials:

Check Valve Inspection [Skyactiv G 2.0]
Airflow Inspection 1. Remove the vacuum hose.. 2. Blow air into the vacuum hose using your mouth from the vacuum pump side and verify that the air flows to the intake manifold side, then blow air from the intake manifold side and verify that the air does not flow to the vacuum pump side. ...

Starter Cut Relay Removal/Installation [MTX]
Advanced Keyless Entry And Push Button Start System Only 1. Disconnect the negative battery cable.. 2. Remove the following parts: Front scuff plate (LH). Front side trim (LH). Side wall. Console. 3. Set the hood release lever out of the way.. 4. Remove the ...

Relay Inspection [Skyactiv G 2.0]
Relay Type Connector type Part name Type A Front fog light relay Headlight relay (HI) Headlight relay (LO) Horn relay TNS relay A/C relay Start ...