Mazda 3 manuals

Mazda 3 Service Manual: Up Switch Inspection [Fw6 A EL]

Mazda 3 Service Manual / Drivetrain / Transmission/Transaxle / Automatic / Up Switch Inspection [Fw6 A EL]

Continuity Inspection

NOTE:

1. Remove the battery cover..

2. Disconnect the negative battery cable..

3. Remove the console..

4. Disconnect the selector lever component connector.


5. Verify that the continuity between selector lever component terminals B and H.


Up switch specification

Test condition

Continuity

Selector lever is in the M position (+) side position.

Continuity

Selector lever is not in the M position (+) side position.

No continuity


Up Switch Inspection [FS5 A EL]
1. Perform the following procedures. a. Remove the battery cover.. b. Disconnect the negative battery cable. c. Remove the console.. d. Disconnect the selector lever component connector. ...

Automatic Transmission Control
...

Other materials:

Rain Sensor Removal/Installation
1. Disconnect the negative battery cable.. 2. Spread open the rain sensor cover in the direction of the arrows and disengage tabs A to remove it. 3. Disconnect the rain sensor connector. 4. Slide rain sensor tab B in the direction of the arrow shown in the figure and detach tab B. ...

Starter Interlock Switch Removal/Installation [C66 M R]
1. Remove the battery cover.. 2. Disconnect the negative battery cable.. 3. Disconnect the starter interlock switch connector. 4. Remove the starter interlock switch from the pedal bracket. 5. Insert a new starter interlock switch into the pedal bracket hole in the direction indicated ...

Oil Seal (Differential) Replacement [Fw6 A EL]
1. Remove the aerodynamic under cover No.2 and the splash shield as a single unit.. 2. Remove the oil seal. a. Drain the ATF.. b. Disconnect the drive shaft (LH) from the transaxle.. c. Disconnect the drive shaft (RH) from the joint shaft.. d. Remove the joint shaft.. CAUTION: ...